Hi all, i've had this gas blowback ksc USP compact for a while now. one day, it just started misfiring out of nowhere.
i loaded it with gas and fired it. It kept on firing till the mag was empty of gas. i've also observed even if the mag is not loaded, i just need to push on the clip that holds the barrel back, and once the barrel shoots in front, it starts to misfire till the mag is empty of gas.

has anyone had an issue with this before, maybe its just that i need to buy a anew magazine or something, the guts of the USP look ok, i just cant figure it out. any advice will be greatly appreciated.
doakes is offline   Reply With Quote
Old November 16th, 2011, 17:28   #2
XZIVR
 
XZIVR's Avatar
 
Join Date: Mar 2011
Location: Calgary, AB
When you say missile, do you mean the slide comes back and it just vents all the gas? or does the slide stay put and it vents out the barrel?
XZIVR is offline   Reply With Quote
Old November 16th, 2011, 17:32   #3
doakes
 
Join Date: Nov 2011
Hey xzivr, thnks for the response. I guess u mean misfire right. Anyway this happens when the slide goes in front. Then the gun starts firing until there is no gas.
doakes is offline   Reply With Quote
Old November 16th, 2011, 17:44   #4
XZIVR
 
XZIVR's Avatar
 
Join Date: Mar 2011
Location: Calgary, AB
Oops sorry, stupid Autocorrect yeah I meant misfire. Okay so it fires full auto then. I have a kwa usp compact and so far it hasn't done that, but I have seen it on other guns including my 226. Check your hammer spring and the mechanism that holds it back. The other thing that can happen Is the part that rests the hammer gets worn and won't hold it cocked.

Take the slide off and pull back the hammer. Does it stay back? Try tapping it and see if it suddenly goes forward on its own. If it does then you probably need to replace the hammer catch.
XZIVR is offline   Reply With Quote
Old November 16th, 2011, 18:00   #5
m102404
Tys
 
m102404's Avatar
 
Join Date: Apr 2006
Location: Toronto
There are a couple of reasons that a gas pistol will act like this
1. The disconnector is broken...or it is not being actuated
2. The sear is broken/worn...or is not resetting correctly
2a. The hammer notches are so worn they're not engaging the sear
3. The nozzle/float valve is broken in such a way that the pistol is not cycling correctly and the slide is not retracting enough to trip the disconnect.

BTW...the slide is the part that goes back and forth...the "clip" that you're referring to is likely the slide release lever.
m102404 is offline   Reply With Quote
Old November 16th, 2011, 18:22   #6
doakes
 
Join Date: Nov 2011
Quote:
Originally Posted by m102404 View Post
There are a couple of reasons that a gas pistol will act like this
1. The disconnector is broken...or it is not being actuated
2. The sear is broken/worn...or is not resetting correctly
2a. The hammer notches are so worn they're not engaging the sear
3. The nozzle/float valve is broken in such a way that the pistol is not cycling correctly and the slide is not retracting enough to trip the disconnect.

BTW...the slide is the part that goes back and forth...the "clip" that you're referring to is likely the slide release lever.
I'm referring to the slide dude, sorry if i wasnt too clear, when i cock the pistol, ie. pull the slide back. When the slide goes in front, the gun starts firing till the gas is out. I dont even need to pull the trigger.
doakes is offline   Reply With Quote
Old November 17th, 2011, 06:16   #7
doakes
 
Join Date: Nov 2011
thanks for this man, ill have to admit, i'm not sure what some of the parts you mentioned are.
ill do a bit of a google and see if i can figure it out. cheers

Quote:
Originally Posted by m102404 View Post
There are a couple of reasons that a gas pistol will act like this
1. The disconnector is broken...or it is not being actuated
2. The sear is broken/worn...or is not resetting correctly
2a. The hammer notches are so worn they're not engaging the sear
3. The nozzle/float valve is broken in such a way that the pistol is not cycling correctly and the slide is not retracting enough to trip the disconnect.
doakes is offline   Reply With Quote
ReplyTop


Go Back   Airsoft Canada > Discussion > Doctor's Corner

Bookmarks


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off


Airsoft Canada

All times are GMT -4. The time now is 12:00.


Powered by vBulletin® Version 3.8.11
Copyright ©2000 - 2024, vBulletin Solutions Inc.